| Product Name | Fisher DVC6200 Digital Valve Positioner |
|---|---|
| Data Interface | Wired |
| Input Signal | Electric |
| Position Control | Throttling Control, On/Off |
| Supply Media | Air, Natural Gas, Nitrogen |
| Communication Protocol | 4-20 MA HART |
|---|---|
| Diagnostics | Yes |
| Max Outlet Pressure | 145 Psig |
| Operating Temperature | Standard Temperature, High Temperature |
| Packaging Details | Cardboard box + protection |
| Operating Temperature | -50°C To +85°C |
|---|---|
| Supply Pressure(Single-Acting) | 20 To 100 Psi Max (1.4 To 6.9 Bar) |
| Supply Pressure(Double-Acting) | 20 To 150 Psi Max (1.4 To 10.3 Bar) |
| Pneumatics Action | Single Or Double Acting, Fail Safe;Rotary And Linear |
| Signal - Communication | HART 5 Or 7 Over 4-20mA |
| Brand | Samson |
|---|---|
| Model | 3730-3 Positioner |
| Product | Positioner |
| Communication | HART Communications |
| Control Loop | 4 To 20 MA |
| Position Control | Throttling Control, On/Off |
|---|---|
| Max Outlet Pressure | 145 Psig |
| Condition | New And Origin |
| Certifications | CSA, FM, ATEX, IECEx, CUTR, Peso, KGS, INMETRO, NEPSI, TIIS, Natural Gas Certified |
| Warranty | One Year |
| Input Pressure | 1.4...6 Bar |
|---|---|
| Maximum Hysteresis | 0.3 % |
| Ambient Air Temperature For Operation | -40...80 °C (-40...176 °F) |
| Communication Port Protocol | HART, 4...20 MA Profibus FOUNDATION Fieldbus |
| IP Degree Of Protection | IP66 |
| Temperature Range | -40 ... +85 °C / -40 ... +185 °F, Standard Version |
|---|---|
| Protection Class | IP66 |
| Communication | HART, FOUNDATION Fieldbus, Profibus PA |
| Approvals | Available For HART, PROFIBUS-PA And FOUNDATION Fieldbus Networks |
| Packaging Details | cardboard box |
| Communication | HART 7 |
|---|---|
| Housing And Cover | Aluminum (Alloy No. 230) Powder Coated |
| Protection Class | IP 66/Type 4X |
| Ambient Temperature | -40 ... 85°C (-40 ... 185°F) |
| Supply Air Pressure | 1.4-10 Bar (20-145 Psig) |
| Ingress Protection | IP66 |
|---|---|
| Diagnostics | Yes |
| Air Consumption | 0.3 SCFM (standard); 0.075 SCFM (low-bleed) @ 60 Psi |
| Communications Protocol | Analog, HART, Foundation Fieldbus, Discrete I/O |
| Operating Temperature | -55 °C To +85 °C (-67 °F To +185 °F) |
| Operating Temperature | -52 To 85 °C (-62 To 185 °F) |
|---|---|
| Current Signal Output | 4 - 20 MA |
| Power Supply | Two - Wire, 4 - 20 MA, 10.0 To 30.0 VDC |
| Power Supply Range | 12.5 To 40 VDC (typically 24 VDC) |
| Communication Protocol | HART Protocol |