| Protection Level | IP66 |
|---|---|
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
| Diagnostic Function | It Can Automatically Detect Faults And Device Status, And Provide Warning And Fault Prompt Information |
| Local Display | 4-digit LCD Screen, Which Can Display Current Analog Input Value, Output Value, Set Value, And Device Status Information |
| Power Supply | 12-42V DC Power Supply |
| Process Control | Flow, Pressure, Temperature, Level |
|---|---|
| Diagnostics | Yes |
| Power Source | Local |
| Area Classification | Explosion Proof, Intrinsically Safe, FISCO, Type N, Flame Proof, Non-incendive For FM |
| Communication Protocol | 4-20 MA HART |
| Set Point | 4 To 20 MA |
|---|---|
| Valve Travel | 3.6 To 300 Mm |
| Opening Angle | 24 To 100° |
| Material | Steel |
| Communication | HART® Field Communication Protocol |
| Communication Interface | HART, FOUNDATION Fieldbus, Profibus PA |
|---|---|
| Action Time | 0.3-30 Seconds |
| Display Screen | LCD Display Screen, Which Can Display Current Position, Power Status, And Other Information |
| Installation Method | Bracket Or Flange Installation |
| Maximum Output Torque | 600 Nm |
| Signal Input | 4~20 MA (HART) |
|---|---|
| Ambient Temp Range | -40 To +85 °C |
| Pneumatic Pressure | 1.4~8 Bar (20~115 Psi) |
| Protection | IP66 |
| Packaging Details | Carton + Wooden crate + Protective packaging |
| Product Name | Azbil Smart Pneumatic Positioners AVP300/301/302 Positioner |
|---|---|
| Brand | Azbil |
| Model | AVP300/301/302 |
| Matrial | Alloy/Steel |
| Valve Style | Positioner |
| Operating Temperature Range | -40℃ To 70℃ |
|---|---|
| Digital Communication Interface | Optional RS485 Modbus RTU Or FOUNDATION Fieldbus Interface |
| Protection Level | IP66 |
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
| Diagnostic Function | It Can Automatically Detect Faults And Device Status, And Provide Warning And Fault Prompt Information |
| Maximum Output Torque | 600 Nm |
|---|---|
| Ambient Temperature | -20℃ ~ +70℃ |
| Protection Level | IP66 |
| Communication Interface | HART, FOUNDATION Fieldbus, Profibus PA |
| Installation Method | Bracket Or Flange Installation |
| Temperature Of Media | Normal Temperature |
|---|---|
| Matrial | Alloy/Steel |
| Sensitivity | ±0.2% F.S |
| Power Supply | Two-wire, 4-20 MA 10.0 To 30.0 VDC |
| Body Material | Stainless Steel, Carbon Steel, Cast Iron |
| Communication Protocol | HART, 4-20mA Analog |
|---|---|
| Input Signal | Electric |
| Operating Temperature | Standard Temperature, High Temperature |
| Supply Media | Air, Non Corrosive Gas |
| Max Outlet Pressure | 101 Psig |