| Communication Protocol | 4-20 HART |
|---|---|
| Process Temperature Range | Up To 1300 °F (705 °C) Or 1922 °F (1050 °C) |
| Ambient Temperature Range | 40 To +149 °F (-40 To +65 °C) |
| Measurement Type | Oxygen, Zirconia - Brazed Disk |
| Dimensions | Probe Length Options From 18 In To 6 Ft |
| Temperature Range | -40 ... +85 °C / -40 ... +185 °F, Standard Version |
|---|---|
| Communication | HART |
| Protection Class | IP66 / NEMA 4X Enclosure |
| Diagnostics | Yes |
| Supply Power | Loop Powered, 4-20 MA |
| Communication Protocol | 4-20 HART |
|---|---|
| Process Temperature Range | Up To 1300 °F (705 °C) Or 1922 °F (1050 °C) |
| Ambient Temperature Range | 40 To +149 °F (-40 To +65 °C) |
| Measurement Type | Oxygen, Zirconia - Brazed Disk |
| Dimensions | Probe Length Options From 18 In To 6 Ft |
| Communication Protocol | HART 7 (3730-3/3731-3) |
|---|---|
| Explosion Proof | 3730=No; 3731=Yes (ATEX/IECEx Ex D) |
| Input Signal | 4-20 MA Two-Wire System (300 Ω Electrical Load)SAMSON AG |
| Mounting Compatibility | Linear/Rotary Control Valves (NAMUR/VDI/VDE)SAMSON AG |
| Protection Class | IP 56/66, NEMA 4 (Aluminum Housing) |
| Acting Type | Single-Acting (03 Suffix) / Double-Acting (06 Suffix) |
|---|---|
| Feedback Type | Standard (HX) / Enhanced Precision (HE) |
| Input Signal | 4-20mA + HART Communication Protocol |
| Supply Pressure | 1.4-8 Bar (0.14-0.8 MPa) |
| Operating Temperature | -40°C To +80°C (Standard Version) |
| Weight | 3.5 Kg |
|---|---|
| Voltage Supply (maximum) | 30 VDC |
| Minimum Required Operating Current | 3.6 MA |
| Repeatability | < 0.25% |
| Input Signal Range | 4 - 20 MA HART |
| Communication Protocol | 4-20 HART |
|---|---|
| Process Temperature Range | Up To 1300 °F (705 °C) Or 1922 °F (1050 °C) |
| Ambient Temperature Range | 40 To +149 °F (-40 To +65 °C) |
| Measurement Type | Oxygen, Zirconia - Brazed Disk |
| Dimensions | Probe Length Options From 18 In To 6 Ft |
| Communication Protocol | 4-20 HART |
|---|---|
| Process Temperature Range | Up To 1300 °F (705 °C) Or 1922 °F (1050 °C) |
| Ambient Temperature Range | 40 To +149 °F (-40 To +65 °C) |
| Measurement Type | Oxygen, Zirconia - Brazed Disk |
| Dimensions | Probe Length Options From 18 In To 6 Ft |
| Power Supply | Loop Powered From 4-20mA Control Signal |
|---|---|
| Load Voltage | 11.0 VDC At 20 MA DC / 10.0 VDC At 4 MA DC |
| Acting Type | Single Or Double |
| Supply Medium | Air Or Nitrogen |
| Digital Communicatin | HART 7 |
| Signal - Communication | HART 7 Over 4-20mA |
|---|---|
| Diagnostics | Positioner Diagnostics/Advanced Diagnostics/Online Valve Diagnostics |
| Construction / Materials | Copper-free Aluminum Housing/Optional 316SS Housing |
| Operating Temperature | -55°C To +85°C |
| Pneumatics Action | Single Acting, Fail Safe /Rotary And Linear |