| Data Interface | Wired |
|---|---|
| Input Signal | Electric |
| Position Control | Throttling Control, On/Off |
| Model Number | DVC6200 |
| Process Control | Flow, Pressure, Temperature, Level |
| Sensitivity | Up To 150:1 |
|---|---|
| Weight | Depends On Specific Instrument |
| Wetted Material | Stainless Steel; 316 / 316L And CF3M |
| Wireless Update Rate | 1 Sec. To 60 Min., User Selectable |
| Measuring Range | Up To 2000 Psi (137,89 Bar) Differential |
| Temperature Range | -40 ... +85 °C / -40 ... +185 °F, Standard Version |
|---|---|
| Protection Class | IP66 |
| Feature | SIL 2 Approved Device |
| Communication | HART, FOUNDATION Fieldbus, Profibus PA |
| Packaging Details | Cardboard box |
| Power Supply | 4-20 MA |
|---|---|
| Ambient Temperature | -58 To 185° F (-50 To 85° C) |
| Diagnostics | Yes |
| Communication | HART Revision 5 Or 7 Protocol |
| Air Supply Pressure | 20 To 150 Psi Max (1.4 To 10.3 Bar) |
| Power Supply | 4-20 MA |
|---|---|
| Ambient Temperature | -58 To 185° F (-50 To 85° C) |
| Diagnostics | Yes |
| Communication | HART Revision 5 Or 7 Protocol |
| Air Supply Pressure | 20 To 150 Psi Max (1.4 To 10.3 Bar) |
| Power Supply | Two-wire, 4-20 MA ,10.0 VDC Plus Line Losses |
|---|---|
| Input Signal Range | 4 - 20 MA |
| Compliance Voltage | 10 To 32 VDC @ 20 MA |
| Effective Resistance | 500 Ω @ 20 MA Typical |
| Communications | HART Protocol (Logix 382X- Only) |
| Rated Flow Coefficient | Maximum CV Value Of 470 |
|---|---|
| Output Signal | 4-20mA, HART, PROFIBUS PA Or FOUNDATION Fieldbus |
| Valve Position Feedback | Provides Digital Position Feedback Through Hall Sensors Or Analog Position Feedback Through Potentiometers |
| Protection Rating | IP66/67 |
| Valve Travel Range | 10mm To 100mm |
| Power Supply | Loop Powered From 4-20mA Control Signal |
|---|---|
| Load Voltage | 11.0 VDC At 20 MA DC / 10.0 VDC At 4 MA DC |
| Acting Type | Single Or Double |
| Supply Medium | Air Or Nitrogen |
| Digital Communicatin | HART 7 |
| Valve Type | Ball Valve, Butterfly Valve, Check Valve, Gate Valve, Globe Valve, Plug Valve |
|---|---|
| Communication Protocol | HART 5 Or HART 7 |
| Analog Input Signal | 4-20 MA DC |
| Electrical Connection | 1 /2 NPT Internal Or M20 |
| Available Mounting | Sliding-stem Linear; Quarter-turn Rotary Applications |
| Connectivity | Flange |
|---|---|
| Material | Stainless Steel, Nickel Alloy, Carbon Steel |
| Output | 4-20 MA With HART 5 Or 7 |
| Operating Temperatures | -330°F To 800°F (-200°C To 427°C) |
| Medium | Gas, Liquid, Steam |