| Antenna Type | Lens Type |
|---|---|
| Explosion Protection | ATEX, FM, IECEx, NEPSI Certified |
| Output Signal | 4 To 20 MA With HART |
| Actuator | Electric |
| Material Process Membrane | 316L, AlloyC, Tantal, Monel, |
| Product Name | Rosemount 3144P + 3051 Smart Transmitter Combo |
|---|---|
| Output Signal | 4-20 MA With HART 5/6/7 |
| Operating Temperature | -40 To +85 °C Ambient, Sensor Dependent |
| Protocol Support | HART, FOUNDATION Fieldbus, PROFIBUS PA |
| 3051 Pressure Types | Differential Pressure , Gauge Pressure , Absolute Pressure |
| Accuracy High Accuracy | ±0.25% |
|---|---|
| Display | Integrated LCD Display |
| Interface | Local Three-button Operation |
| Communication | Supports HART Protocol |
| Data | Built-in Data Logger |
| Power Supply | (100~240)VAC, 50/60Hz / (18~28)VDC |
|---|---|
| Accuracy | ±0.3%FS / ±0.5%FS |
| Ambient Temperature | Main Unit: (-20~60)℃, Probe: (-20~80)℃ |
| Storage Temperature | (-20~80)℃ |
| Protection Rating | Main Unit: IP65, Probe: IP68 |
| Flange Options | ANSI Class 150 To 1500 |
|---|---|
| Sensitivity | Up To 150:1 |
| Measurement Range | Digital Or Analog |
| Measuring Range | Up To 2000 Psi (137,89 Bar) Differential |
| Wireless Range | Internal Antenna (225 M) |
| Product Name | Radar Measurement Micropilot FMR56 |
|---|---|
| Process Pressure/max. Overpressure Limit | Vacuum...3 Bar(Vacuum...43.5 Psi) |
| Process Connection | UNI DN80...DN150(3"...6") |
| Communication | 4...20 MA HART PROFIBUS PA FOUNDATION Fieldbus |
| Measuring Principle | Level Radar Solid |
| Wetted Material | Stainless Steel; 316 / 316L And CF3M |
|---|---|
| Weight | Depends On Specific Instrument |
| Wireless Range | Internal Antenna (225 M) |
| Measuring Range | Up To 2000 Psi (137,89 Bar) Differential |
| Sensitivity | Up To 150:1 |
| Product Name | Radar Measurement Micropilot FMR62 |
|---|---|
| Process Pressure/max. Overpressure Limit | Vacuum...+25 Bar(Vacuum...+362.6 Psi) |
| Measuring Principle | Level Radar |
| Communication | 4...20 MA HART |
| Process Temperature | -40...+200 °C (-40...+392 °F) |
| Measuring Range | 100 Mbar To 40 Bar (absolute/gauge) |
|---|---|
| Process Temperature | -40°C To +100°C |
| Protection Class | IP67 (standard), IP68 (optional) |
| Output Signal | 4-20mA+HART, Optional Profibus PA/FF |
| Power Supply | 10.5-35V DC (Ex I: 10.5-30V DC) |
| Frequency | W-band (~80 GHz) |
|---|---|
| Control Signal | 4 - 20mA, 0 - 10V |
| Housing Material | Aluminum, Stainless Steel |
| Protective Class | IP66 |
| Wetted Material | Stainless Steel; 316 / 316L And CF3M |