| Humidity Range | 0% To 95% (non-condensing) |
|---|---|
| Communication Interface | HART, FoxCom, RS-232, RS-485 |
| Output Stability | ±0.01% Of Output Reading Per Hour |
| Optional Accessories | Pressure Modules, Temperature Sensors, Communication Cables, PC Software |
| Battery Life | Approx. 20 Hours Continuous Use At 20 MA Output |
| Safety Features | Overvoltage Protection, Reverse Polarity Protection, Short-circuit Protection |
|---|---|
| Ramp Function | User-defined Ramp Function With Adjustable Time |
| Optional Accessories | Pressure Modules, Temperature Sensors, Communication Cables, PC Software |
| Step Function | 25% Step, 100% Step, User-defined Step |
| Certifications | CE, CSA, FM, ATEX, IECEx, GOST-R |
| Measurement Range | 0-24 MA DC |
|---|---|
| Display | LCD Display, 2 Lines X 16 Characters |
| Output Resolution | 0.001 MA |
| Battery Life | Approx. 20 Hours Continuous Use At 20 MA Output |
| Accuracy | 0.025% Full Scale |
| Safety Features | Overvoltage Protection, Reverse Polarity Protection, Short-circuit Protection |
|---|---|
| Programmability | Programmable Through FoxCom Or PC Software |
| Optional Accessories | Pressure Modules, Temperature Sensors, Communication Cables, PC Software |
| Power Output | 24V DC Nominal, 20 MA Max |
| Ramp Function | User-defined Ramp Function With Adjustable Time |
| Battery Life | Approx. 30 Hours Continuous Use At 20 MA Output |
|---|---|
| Accessories | Carrying Case, Test Leads, Alligator Clips, User Manual, Certificate Of Calibration |
| Power Output | 24V DC Nominal, 30 MA Max |
| Optional Accessories | Pressure Modules, Temperature Sensors, Communication Cables, PC Software |
| Power Supply | 9V DC 4 X 1.5V AA Batteries Or Rechargeable Battery |
| Accuracy | 0.01% Full Scale |
|---|---|
| Certifications | CE, CSA, FM, ATEX, IECEx, GOST-R |
| Optional Accessories | Pressure Modules, Temperature Sensors, Communication Cables, PC Software |
| Power Supply | 9V DC 4 X 1.5V AA Batteries Or Rechargeable Battery |
| Output Resolution | 0.001 MA |
| Type | Vortex Flowmeter |
|---|---|
| Material | Stainless Steel |
| Temperature | Temperature |
| Ingress Protection | IP 66/67 |
| Pressure | Max. 100 Bar / 1450 Psi |
| Area Classification | Intrinsically Safe, Explosion Proof, Dust Ignition Proof, Flame Proof, Non-incendive, Type N |
|---|---|
| Certifications | CSA, FM, ATEX, KGS, Peso, CIMFR, NEPSI, TIIS, Ukraine Metrology, Belarus Metrology, Kazakhstan Metrology, IECEx, INMETRO, CUTR |
| Communication Protocol | HART®, 4-20mA Analog |
| Data Interface | Wired |
| Diagnostics | Yes |
| Medium | Water, Gas, Steam |
|---|---|
| Max. Process Pressure | PN 100, Class 600, 20K |
| Digital Communication | HART, PROFIBUS PA, FOUNDATION Fieldbus |
| Degree Of Protection | IP66/67 |
| Medium Temperature Range | Standard: -40 To +260 °C (-40 To +500 °F) |
| Accessories | Carrying Case, Test Leads, Alligator Clips, User Manual, Certificate Of Calibration |
|---|---|
| Power Output | 24V DC Nominal, 30 MA Max |
| Output Resolution | 0.001 MA |
| Power Supply | 9V DC 4 X 1.5V AA Batteries Or Rechargeable Battery |
| Display | LCD Display, 2 Lines X 16 Characters |