| Input Signal | 4~20mA DC |
|---|---|
| Impedance | 250±15Ω |
| Supply Pressure | 0.14~0.7MPa |
| Stroke | 10~150mm 0~90º |
| Air Connection | P(NPT) 1/4 |
| Accuracy | 0.025% Full Scale |
|---|---|
| Output Stability | ±0.01% Of Output Reading Per Hour |
| Communication Interface | HART, FoxCom, RS-232, RS-485 |
| Display | LCD Display, 2 Lines X 16 Characters |
| Weight | Approx. 300g |
| Measurement Range | 0-24 MA DC |
|---|---|
| Display | LCD Display, 2 Lines X 16 Characters |
| Output Resolution | 0.001 MA |
| Battery Life | Approx. 20 Hours Continuous Use At 20 MA Output |
| Accuracy | 0.025% Full Scale |
| Accessories | Overload Protection, Manual Operation, Protective Cover, And Transition Plate |
|---|---|
| Positioning Accuracy | Typically ±0.5% |
| Valve Stroke Range | Typically 20mm, 40mm, 60mm, Or 100mm |
| Mounting | Vertical Or Suspended Mounting Options |
| Output Signal | Typically 4-20mA Or 0-10VDC |
| Operating Temperature Range | -40°C To +85°C |
|---|---|
| Positioning Accuracy | Typically ±0.5% |
| Mounting | Vertical Or Suspended Mounting Options |
| Valve Stroke Range | Typically 20mm, 40mm, 60mm, Or 100mm |
| Power Supply Voltage | 24VDC Or 110-240VAC |
| Data Interface | Wired |
|---|---|
| Certifications | CSA, FM, ATEX, IECEx, CUTR, PED, UL, Peso, KGS, INMETRO, NEPSI, ANZEx |
| Communication Protocol | HART, 4-20mA Analog |
| Product | Digital Positioner |
| Area Classification | Intrinsically Safe, Non-incendive For CSA And FM |
| Supply Media | Air, Non Corrosive Gas |
|---|---|
| Shell Material | Industrial Aluminum Housing |
| Certifications | CSA, FM, ATEX, IECEx, CUTR, PED, UL, Peso, KGS, INMETRO, NEPSI, ANZEx |
| Model Number | DVC2000 |
| Product | Digital Positioner |
| Type | Digital Positioner |
|---|---|
| Diagnostics | Yes |
| Mounting Type | Integral Mounted |
| Condition | New And Origin |
| Area Classification | Intrinsically Safe, Non-incendive For CSA And FM |
| Operating | -40° F To 185° F (-40° C To 85° C) |
|---|---|
| Name | Masoneilan SVI FF |
| Ambient Humidity | 10 To 95% Non-condensing |
| Customized Support | OEM, ODM, OBM |
| Supply Pressure Effect | 0.05% Per Psi Unit |
| Safety Features | Overvoltage Protection, Reverse Polarity Protection, Short-circuit Protection |
|---|---|
| Ramp Function | User-defined Ramp Function With Adjustable Time |
| Optional Accessories | Pressure Modules, Temperature Sensors, Communication Cables, PC Software |
| Step Function | 25% Step, 100% Step, User-defined Step |
| Certifications | CE, CSA, FM, ATEX, IECEx, GOST-R |