| Product Name | Radar Measurement Micropilot FMR56 |
|---|---|
| Process Pressure/max. Overpressure Limit | Vacuum...3 Bar(Vacuum...43.5 Psi) |
| Process Connection | UNI DN80...DN150(3"...6") |
| Communication | 4...20 MA HART PROFIBUS PA FOUNDATION Fieldbus |
| Measuring Principle | Level Radar Solid |
| Pressure Range | Up To 40 Bar |
|---|---|
| Manufacturer | Various Manufacturers |
| Rangedown | Up To 150:1 |
| Protocol Support | HART, FOUNDATION Fieldbus, PROFIBUS PA |
| Control Signal | 4-20mA/0-10V |
| Manufacturer | Various Manufacturers |
|---|---|
| Ambient Relative Humidity | ≤93%RH |
| Power Supply | AC Or DC |
| Calibration | Single Calibration |
| Rangedown | Up To 150:1 |
| Sensitivity | Up To 150:1 |
|---|---|
| Weight | Depends On Specific Instrument |
| Wetted Material | Stainless Steel; 316 / 316L And CF3M |
| Wireless Update Rate | 1 Sec. To 60 Min., User Selectable |
| Measuring Range | Up To 2000 Psi (137,89 Bar) Differential |
| Protection Level | IP67 |
|---|---|
| Material | Aluminum Alloy Or Stainless Steel |
| Process Temperature | -40℃~+80℃/-40℃~+150℃ |
| Communication Output | RS485,MODBUS;HART |
| Transmitter Output | 4~20mA |
| Measuring Range | (0~5)m / (0~10)m |
|---|---|
| Ambient Temperature | (-20~80)℃ |
| Protection Level | Instrument: IP65, Probe: IP68 |
| Power Supply | (18~28)VDC |
| Packaging Details | Cardboard box + protection |
| Product Name | Radar Measurement Micropilot FMR62 |
|---|---|
| Process Pressure/max. Overpressure Limit | Vacuum...+25 Bar(Vacuum...+362.6 Psi) |
| Measuring Principle | Level Radar |
| Communication | 4...20 MA HART |
| Process Temperature | -40...+200 °C (-40...+392 °F) |
| Sensitivity | Up To 150:1 |
|---|---|
| Weight | Depends On Specific Instrument |
| Wetted Material | Stainless Steel; 316 / 316L And CF3M |
| Wireless Update Rate | 1 Sec. To 60 Min., User Selectable |
| Measuring Range | Up To 2000 Psi (137,89 Bar) Differential |
| Temperature | -40...+240°C / -40...+465°F |
|---|---|
| Ingress Protection | IP 66/67 |
| Pressure | Max. 100 Bar / 1450 Psi |
| Repeatability | ±0.1% Of Measured Value |
| Measurement Range | 4...20 MA (max. 20.8 MA) + HART Protocol |
| Medium Temperature Range | Standard: –50 To +150 °C (–58 To +302 °F) Option: –50 To +240 °C (–58 To +464 °F) High Temperatur Option: –50 To +350 °C (–58 To +662 °F) Option: –196 To +150 °C (–320 To +302 °F) |
|---|---|
| Volume Flow (liquid) | ±0.10 % |
| Measuring Range | 0 To 2 200 000 Kg/h (0 To 80 840 Lb/min) |
| Measured Variables | Mass Flow, Density, Temperature, Volume Flow, Corrected Volume Flow, Reference Density, Concentration |
| Nominal Diameter Range | DN 8 To 250 (⅜ To 10") |