| Output Signal | Two-wire 4-20 MA With HART Protocol. |
|---|---|
| Accuracy | ±2 Mm (performance Standard For Liquids). |
| Power Supply | Loop-powered (two-wire) |
| Packaging Details | standard |
| Delivery Time | 8-12 weeks |
| Ingress Protection | IP65 |
|---|---|
| Material | Stainless Steel |
| Power Supply | 12-45 V DC |
| Ambient Temperature | -29°C To 93°C (amplifier); -40°C To 104°C (sensor) |
| Relative Humidity | 0-100% RH |
| Output Signal | Two-wire 4-20 MA With HART Protocol. |
|---|---|
| Accuracy | ±2 Mm (performance Standard For Liquids). |
| Power Supply | Loop-powered (two-wire) |
| Packaging Details | standard |
| Delivery Time | 8-12 weeks |
| Control Mode | Manual/Automatic |
|---|---|
| Measurement Temp | (0~50.0)℃ |
| Medium Temperature | -196 To 425 °C |
| Cooling Type | Forced Cooling |
| Communication Interface | Depends On Specific Instrument |
| Flange Options | ANSI Class 150 To 1500 |
|---|---|
| Measuring Range | Up To 2000 Psi (137,89 Bar) Differential |
| Precision | High Precision |
| Sensitivity | Up To 150:1 |
| Wetted Material | Stainless Steel; 316 / 316L And CF3M |
| Measuring Principle | Vibration Liquids |
|---|---|
| Ambient Temperature | -50 °C...+70 °C (-58 °F...+158 °F) |
| Process Temperature | -50 °C...+150 °C (-58 °F...+302 °F) |
| Process Pressure / Max. Overpressure Limit | Vacuum...100 Bar |
| Min. Density Of Medium | 0.5g/cm³(0.4g/cm³ Optional) |
| Process Temperature(Standard) | -40 To +125 °C (-40 To +257 °F) |
|---|---|
| Process Connections | Threaded, Flange, Hygienic, Remote Seal |
| Applications | Hygienic, Chemical, And Oil & Gas Applications |
| Wetted Materials | 316L Stainless Steel, Alloy C, Tantalum (optional) |
| Output Signal | 4 To 20 MA With HART |
| Communication Protocol | 4-20 HART |
|---|---|
| Process Temperature Range | Up To 1300 °F (705 °C) Or 1922 °F (1050 °C) |
| Ambient Temperature Range | 40 To +149 °F (-40 To +65 °C) |
| Measurement Type | Oxygen, Zirconia - Brazed Disk |
| Dimensions | Probe Length Options From 18 In To 6 Ft |
| Output / Protocol | 4-20 MA With HART; FOUNDATION Fieldbus; PROFIBUS PA |
|---|---|
| Display/Interface | LCD Display, LCD Display With Local Operator Interface (LOI), Or LED |
| IP Rating | IP66 |
| Mounting / Housing | Head Mount (DIN A), Field Mount, Rail Mount |
| Diagnostics | Yes |
| Measuring Principle | Vibration Liquids |
|---|---|
| Ambient Temperature | -50 °C...+70 °C (-58 °F...+158 °F) |
| Process Temperature | -50 °C...+150 °C (-58 °F...+302 °F) |
| Process Pressure / Max. Overpressure Limit | Vacuum...100 Bar |
| Min. Density Of Medium | 0.5g/cm³(0.4g/cm³ Optional) |