| Process/Valve Temperature Range | -196°C 至 +450°C 以上 |
|---|---|
| Linearity | ±0.5% To ±2.0% Of Span |
| Mounting | Direct Mount On Linear (stem) Or Rotary (ISO 5211) Actuators |
| Input/Output Connections | Conduit Entries Or Integral Connectors |
| Output Air Pressure | 0 To 100% Of Supply Pressure |
| Input Resistance | 400 Wmax/20 MA |
|---|---|
| Approval Bodies | Intrinsically Safe CCC |
| Weight | 1.7kg(3.7 Lbs) |
| Vibration Characteristics2G At 5 To 400 Hz | 2G At 5 To 400 Hz |
| Input | 4 To 20 MA HART Communication |
| Port | Main Ports |
|---|---|
| Model | EDP300 |
| Item | Intelligent Valve Positioner |
| Feature | Durable |
| Packaging Details | Packing type: cardboard box Dimension: Weight: Approx. 3.5Kg/set |
| Valve Type | Ball Valve, Butterfly Valve, Check Valve, Gate Valve, Globe Valve, Plug Valve |
|---|---|
| Supply Voltage | 8-30 VDC |
| Communication Protocol | HART 5 Or HART 7 |
| Analog Input Signal | 4-20 MA DC |
| Electrical Connection | 1 /2 NPT Internal Or M20 |
| Customized Support | OEM |
|---|---|
| Communication Protocol | HART, 4-20mA Analog |
| Input Signal | Electric |
| Max Outlet Pressure | 101 Psig |
| Cardboard Box + Protection | Air, Non Corrosive Gas |
| Housing Material | Low Copper Chromated Aluminum (ASTM A360) |
|---|---|
| Protection Rating | IP66 / NEMA 4X |
| Weight | 2 Kg (4.5 Lb) |
| Input Power/Signal | 3.2-24 MA; Compliance: 9 VDC At 20 MA, 11 VDC At 4 MA |
| Optional Outputs | Two Solid-state Switches (1A/30 VDC); 4-20 MA Position Retransmit |
| Communication Protocol | 4-20 MA HART |
|---|---|
| Data Interface | Wired |
| Diagnostics | Yes |
| Input Signal | Electric |
| Max Outlet Pressure | 145 Psig |
| Applicable Actuator | Pneumatic Single And Double Acting, Linear And Rotary Motion Actuator |
|---|---|
| Input Signal | 4-20 MA DC |
| Communication System | SFN Communication (Model AVP300/301/302)/HART6(Model AVP302) |
| Output Signal | 4-20 MA DC (Travel Transmission) |
| Lightning Protection | Peak Value Of Voltage Surge: 12 KV/Peak Value Of Current Surge: 1000 A |
| Standard Or Nonstandard | Standard |
|---|---|
| Communication Protocol | 4-20 MA HART |
| Accuracy | ±0.50% Of Output Span (independent Linearity) |
| Rangedown | Up To 10:1 (5:1 For Range 1) |
| Media | Gas |
| Operating Temperature Limits | -58°F To 185°F (-50°C To 85°C) |
|---|---|
| Supply Pressure Effect | 0.05% Per Psi |
| Insulation Resistance | Greater Than 10 G Ohms At 50% RH |
| Relative Humidity | 10 To 90% Non-condensing |
| Packaging Details | Cardboard boxes/Wooden crates |