| Communication Protocol | 4-20mA Analog |
|---|---|
| Model Number | 3582i |
| Mounting Type | Actuator Mounted |
| Data Interface | Wired |
| Safety Certifications | NIL |
| Zero Point Drift | Less Than 0.1% Of The Maximum Travel Value |
|---|---|
| Valve Travel Range | 10mm To 100mm |
| Valve Connection | ISO 5211 Direct Mounting Or VDI/VDE 3845 Mounting With Adapter |
| Protection Rating | IP66/67 |
| Linearity | Less Than 0.5% Of The Maximum Travel Value |
| Input Signal | 4-20mA DC, 1-5V DC, 0-10V DC, HART Protocol, Etc |
|---|---|
| Protection Level | IP66 |
| Diagnostic Function | It Can Automatically Detect Faults And Device Status, And Provide Warning And Fault Prompt Information |
| Accuracy | Up To 0.075% Under Nominal Conditions |
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
| Model Number | SVI II |
|---|---|
| Materials | Copper-free Aluminum Housing |
| Operating Temperature | -50°C To +85°C |
| Hysteresis + DeadBand | +/- 0.3 Percent Full Span |
| Linearity | +/- 1 Percent Full Scale |
| Temperature Range | -320 To +842 °F (-196 To +450 °C) |
|---|---|
| Std. Materials | Cast Iron, Carbon Steel, Stainless Steel, Monel |
| Pressure Rating | Class 125 To 300 |
| Warranty | 1 Year |
| ANSI Class | 150 To 2500 |
| Condition | New |
|---|---|
| Hysteresis + DeadBand | +/- 0.3 Percent Full Span |
| Minimum Current Signal | 3.2 MA |
| Pneumatics | Air Or Sweet Natural Gas – Regulated And Filtered |
| Signal Communication | HART 5 Or 7 Over 4-20mA |
| Condition | New |
|---|---|
| Hysteresis + DeadBand | +/- 0.3 Percent Full Span |
| Minimum Current Signal | 3.2 MA |
| Pneumatics | Air Or Sweet Natural Gas – Regulated And Filtered |
| Signal Communication | HART 5 Or 7 Over 4-20mA |
| Input Signal Range | 4-20 MA (split Range Minimum Amplitude 8 MA) |
|---|---|
| Air Supply | 20 To 100 Psig (regulate 5 To 10 Psi Above Actuator Spring Range) |
| Actuator Stroke | 20 Mm To 150 Mm Or 55 ° To 90 ° |
| Action | Single Acting/fail Vent/Double Acting |
| Operating Temperature | -4 °F To +158 °F |
| Operating Temperature | -40°C To +85°C (-40°F To +185°F) |
|---|---|
| Ingress Protection | IP66 |
| Input Signal | 4-20 MA DC |
| Supply Air Pressure | 1.4 To 6 Bar (20 To 90 Psi) |
| Electrical Connections | 1/4 NPT |
| Rated Flow Coefficient | Maximum CV Value Of 470 |
|---|---|
| Output Signal | 4-20mA, HART, PROFIBUS PA Or FOUNDATION Fieldbus |
| Valve Position Feedback | Provides Digital Position Feedback Through Hall Sensors Or Analog Position Feedback Through Potentiometers |
| Protection Rating | IP66/67 |
| Valve Travel Range | 10mm To 100mm |