| Turndown | 400:1 |
|---|---|
| Response Time | 125ms |
| Mounting Type | Direct Connect/Low Profile/Biplanar |
| Measurement Accuracy | +/- 0.05 % Of Reading |
| Maximum Pressure | 3000 Psi/207 Bar |
| Temperature | -52°C To 85°C (-61.6°F To 185°F) |
|---|---|
| Minimum Input Pressure | 1.5 Bar (22 PSI) |
| Operating Humidity | 0 - 100% Non-condensing |
| Repeatability | ≤0.25% |
| Maximum Input Pressure | 10.3 Bar (150 PSI) |
| Input Signal Range | 4 - 20 MA HART |
|---|---|
| Input Pressure Range | 1.5 To 6.0 Bar |
| Minimum Required Operating Current | 3.6 MA |
| Voltage Supply (maximum) | 30 VDC |
| Humidity | 0-100% Non-condensing |
| Operating Temperature | -52 To 85 °C (-62 To 185 °F) |
|---|---|
| Current Signal Output | 4 - 20 MA |
| Power Supply | Two - Wire, 4 - 20 MA, 10.0 To 30.0 VDC |
| Power Supply Range | 12.5 To 40 VDC (typically 24 VDC) |
| Communication Protocol | HART Protocol |
| Input Signal Options | 4-20 MA (analog), HART, FOUNDATION Fieldbus |
|---|---|
| Air Supply Pressure | 3-7 Bar |
| Protection Rating | IP66 |
| Accuracy | ≤ 0.25 % |
| Temperature Range | -52 °C To +85 °C (-62 °F To +185 °F) |
| Product Name | Gas Regulator Types 1301F And 1301G Pressure Regulators |
|---|---|
| Body Size And End Connection Style | 1/4 NPT |
| Maximum Inlet Pressure | Air And Gas: 6000 Psig / 414 Bar |
| Outlet Pressure Ranges | Type 1301F: 10 To 225 Psig /Type 1301G: 200 To 500 Psig |
| Standard Temperature Capabilities | Nylon Disk & Neoprene Gaskets: -20 To 180°F / -29 To 82°C |
| Suitable Gas | Air |
|---|---|
| Body Size And End Connection Style | 1/2 NPT |
| Maximum Emergency Outlet Pressure | 150 Psi / 10.3 Bar Over Outlet Pressure |
| Temperature Capabilities | -40 To 180°F / -40 To 82°C |
| Maximum Inlet Pressure (Body Rating) | All Filtered: 250 Psig / 17.2 Bar;All Unfiltered: 400 Psig / 27.6 Bar |
| Communication Protocol | HART 7 |
|---|---|
| Maximum Output Pressure | 145 Psig |
| Input Signal | 4-20 MA DC, 24 VDC |
| Position Control | Throttling Control, On/off |
| Media Supply | Air Or Natural Gas |
| Communication Protocol | HART 7 |
|---|---|
| Maximum Output Pressure | 145 Psig |
| Input Signal | 4-20 MA DC, 24 VDC |
| Position Control | Throttling Control, On/off |
| Media Supply | Air Or Natural Gas |
| Output Signal | 4-20 MA (Active Or Passive Loop), HART Protocol (optional) |
|---|---|
| Ambient Temperature | -40°C To +85°C |
| Ingress Protection | IP66 / IP67 |
| Typical Applications | Separator Level, Storage Tanks, Process Vessels, Oil & Gas, Chemical |
| Power Supply | 12-30 VDC (Loop-powered) |