| Media | Chemical Liquid |
|---|---|
| Body Type | Eccentric Segmental Ball Valve |
| Body Size | 1"(25A)~12"(300A) |
| Body Rating | ANSI Class 150~600, JIS 10K~40K |
| Fluid Temperature | -45~+400°C |
| Valve Type | Ball Valve, Butterfly Valve, Check Valve, Gate Valve, Globe Valve, Plug Valve |
|---|---|
| Communication Protocol | HART 5 Or HART 7 |
| Analog Input Signal | 4-20 MA DC |
| Electrical Connection | 1 /2 NPT Internal Or M20 |
| Available Mounting | Sliding-stem Linear; Quarter-turn Rotary Applications |
| Valve Type | Ball Valve, Butterfly Valve, Check Valve, Gate Valve, Globe Valve, Plug Valve |
|---|---|
| Communication Protocol | HART 5 Or HART 7 |
| Analog Input Signal | 4-20 MA DC |
| Electrical Connection | 1 /2 NPT Internal Or M20 |
| Available Mounting | Sliding-stem Linear; Quarter-turn Rotary Applications |
| Valve Type | Concentric Segmental Ball Valve |
|---|---|
| Nominal Diameter | 1(25A)-12(300A), 1(25A)-18(450A), 6(150A)-24(600A) |
| Fluid Temperature | -45 To +500°C |
| Connection Type | Wafer, Flanged(RF, FF, RTJ), Flanged(RF, RTJ) |
| Body Material | SCPH2/WCB, SCS13A/ CF8, SCS14A/CF8M, SCS13A, SCS14A |
| Valve Type | Parallel Slide Valve |
|---|---|
| Sealing Type | Metal-to-Metal Contact Seal |
| Main Application | Thermal Power Plant Petrochemical Industry |
| Key Performance | High Shut-Off Performance |
| Operating Conditions | High Pressure High/Low Temperature |
| Communication Protocol | HART, 4-20mA Analog |
|---|---|
| Data Interface | Wired |
| Diagnostics | Yes |
| Input Signal | Electric |
| Max Outlet Pressure | 101 Psig |
| Communication Protocol | 4-20 MA HART |
|---|---|
| Data Interface | Wired |
| Diagnostics | Yes |
| Input Signal | Electric |
| Max Outlet Pressure | 145 Psig |
| Signal - Communication | HART 7 Over 4-20mA |
|---|---|
| Diagnostics | Positioner Diagnostics/Advanced Diagnostics/Online Valve Diagnostics |
| Construction / Materials | Copper-free Aluminum Housing/Optional 316SS Housing |
| Operating Temperature | -55°C To +85°C |
| Pneumatics Action | Single Acting, Fail Safe /Rotary And Linear |
| Communication Protocol | 4-20 MA HART |
|---|---|
| Data Interface | Wired |
| Diagnostics | Yes |
| Input Signal | Electric |
| Max Outlet Pressure | 145 Psig |
| Signal - Communication | HART 7 Over 4-20mA |
|---|---|
| Diagnostics | Positioner Diagnostics/Advanced Diagnostics/Online Valve Diagnostics |
| Construction / Materials | Copper-free Aluminum Housing/Optional 316SS Housing |
| Operating Temperature | -55°C To +85°C |
| Pneumatics Action | Single Acting, Fail Safe /Rotary And Linear |