| Accuracy | +/-0.5% |
|---|---|
| Measurement Range | 9 Dm³/min To 22500 M³/h (2.5 To 100000 Gal/min) |
| Medium | Water, Liquid |
| Max Process Pressure | 300, 20K,PN 40 |
| Protection | IP66/67 (option: IP68) |
| Measurement Range | 0.1...20 M/s (200:1) |
|---|---|
| Process Temperature | -40...+200°C/ -40...+392°F |
| Digital Outputs | FOUNDATION Fieldbus, HART, Profibus-PA, Profibus-DP, Modbus RTU |
| Analogue Outputs | 4...20 MA |
| Measured Media | Liquids |
| Measurement Range | 0.1...20 M/s (200:1) |
|---|---|
| Process Temperature | -40...+200°C/ -40...+392°F |
| Digital Outputs | FOUNDATION Fieldbus, HART, Profibus-PA, Profibus-DP, Modbus RTU |
| Analogue Outputs | 4...20 MA |
| Measured Media | Liquids |
| Measuring Principle | Electromagnetic |
|---|---|
| Output Signal | 4–20 MA, HART, Modbus, Profibus, EtherNet/IP |
| Special Features | Heartbeat Technology, Touch Control, Backlit Display |
| Ingress Protection | IP66/67 (standard), IP68 (optional) |
| Maximum Pressure | PN 40 / Class 300 |
| Nominal Diameter | DN15–DN600 (½″–24″) |
|---|---|
| Output Signal | 4–20 MA, HART, Modbus, Profibus, EtherNet/IP |
| Electrode Material | 316L / Hastelloy / Tantalum / Platinum / Titanium |
| Accuracy | ±0.5% ±1 Mm/s (optional: ±0.2%) |
| Maximum Pressure | PN 40 / Class 300 |
| Product Name | Rosemount 644 Temperature Transmitter |
|---|---|
| Material | Aluminum, Stainless Steel |
| Sensor Input Channels | Single Sensor Input |
| Output Signal | 4-20 MA With HART 5/6/7 |
| 4-20 MA With HART 5/6/7 | 12-42.4 VDC (minimum 10.5 VDC For Digital Only) |
| Product Name | Rosemount 644 Temperature Transmitter |
|---|---|
| Material | Aluminum, Stainless Steel |
| Sensor Input Channels | Single Sensor Input |
| Output Signal | 4-20 MA With HART 5/6/7 |
| 4-20 MA With HART 5/6/7 | 12-42.4 VDC (minimum 10.5 VDC For Digital Only) |
| Product Name | Pressure Measurement Prosonic M FMU40 Level Measurement Differential Pressure Transmitter For Endress+Hauser |
|---|---|
| Model | FMU40 |
| Critical Service | Noise Abatement, Cavitation, Erosive, Low Flow, Corrosive |
| Brand | Endress+Hauser |
| Material | Carbon Steel, Stainless, Duplex, Alloy |
| Medium | Water, Gas, Steam |
|---|---|
| Max. Process Pressure | PN 100, Class 600, 20K |
| Digital Communication | HART, PROFIBUS PA, FOUNDATION Fieldbus |
| Degree Of Protection | IP66/67 |
| Medium Temperature Range | Standard: -40 To +260 °C (-40 To +500 °F) |
| Product Name | Rosemount 3144P Temperature Transmitter |
|---|---|
| Output Signal | 4-20 MA With HART 5/6/7 |
| Housing Material | Aluminum, Stainless Steel |
| Protocol Support | HART, FOUNDATION Fieldbus, PROFIBUS PA (depending On Model Variant) |
| Ingress Protection | IP66/67, NEMA 4X |