| Product Name | Radar Measurement Micropilot FMR62 |
|---|---|
| Process Pressure/max. Overpressure Limit | Vacuum...+25 Bar(Vacuum...+362.6 Psi) |
| Measuring Principle | Level Radar |
| Communication | 4...20 MA HART |
| Process Temperature | -40...+200 °C (-40...+392 °F) |
| Product Name | Radar Measurement Micropilot FMR62 |
|---|---|
| Process Pressure/max. Overpressure Limit | Vacuum...+25 Bar(Vacuum...+362.6 Psi) |
| Measuring Principle | Level Radar |
| Communication | 4...20 MA HART |
| Process Temperature | -40...+200 °C (-40...+392 °F) |
| Product Name | Radar Measurement Micropilot FMR56 |
|---|---|
| Process Pressure/max. Overpressure Limit | Vacuum...3 Bar(Vacuum...43.5 Psi) |
| Process Connection | UNI DN80...DN150(3"...6") |
| Communication | 4...20 MA HART PROFIBUS PA FOUNDATION Fieldbus |
| Measuring Principle | Level Radar Solid |
| Product Name | Radar Measurement Micropilot FMR56 |
|---|---|
| Process Pressure/max. Overpressure Limit | Vacuum...3 Bar(Vacuum...43.5 Psi) |
| Process Connection | UNI DN80...DN150(3"...6") |
| Communication | 4...20 MA HART PROFIBUS PA FOUNDATION Fieldbus |
| Measuring Principle | Level Radar Solid |
| Medium | Water, Gas, Steam |
|---|---|
| Max. Process Pressure | PN 100, Class 600, 20K |
| Digital Communication | HART, PROFIBUS PA, FOUNDATION Fieldbus |
| Degree Of Protection | IP66/67 |
| Medium Temperature Range | Standard: -40 To +260 °C (-40 To +500 °F) |
| Accuracy | ± 0.2% |
|---|---|
| Medium | Water, Liquid |
| Type | Electromagnetic Meters |
| Material | Stainless Steel |
| Connectivity | Flange |
| Brand | Feejoy |
|---|---|
| Frequency | 76~81GHz |
| Rated Pressure | -0.1~2.5MPa |
| Rated Temperature | -40~200℃ |
| Ambient Temperature | -20~80℃ |
| Accuracy | Standard: Up To 0.05 % |
|---|---|
| Process Temperature | -40°C...+110°C |
| Rated Temperature | -40~200℃ |
| Communication Interface | Depends On Specific Instrument |
| Condition | New |
| Product Name | Endress+Hauser Radar Level Micropilot FMR20 For Water & Wastewater |
|---|---|
| Accuracy | +/- 2 Mm (0,08") |
| Process Temperature | -40...+80°C (-40...+176°F) |
| Process Pressure Absolute | -1...3 Bar (-14,5...43 Psi) |
| Max. Measurement Distance | 15 M (49.2 Ft), DN80_ 20 M (65.6 Ft) |
| Process Temperature(Standard) | -40 To +125 °C (-40 To +257 °F) |
|---|---|
| Process Connections | Threaded, Flange, Hygienic, Remote Seal |
| Applications | Hygienic, Chemical, And Oil & Gas Applications |
| Wetted Materials | 316L Stainless Steel, Alloy C, Tantalum (optional) |
| Output Signal | 4 To 20 MA With HART |