| Nominal Diameter At Inlet | DN 25 - DN 100 | 1" - 4" |
|---|---|
| Actual Orifice Diameter D | 20 - 74 Mm | 0.79 - 2.91 In |
| Actual Orifice Area A | 314 - 4301 Mm² | 0.487 - 6.666 In² |
| Pressure | 2.5 - 100 Bar | 36 - 1450 Psig |
| Flange Rating Inlet | PN 63 - PN 160 | CL150 - CL1500 |
| Nominal Diameter At Inlet | DN 25 - DN 100 | 1" - 4" |
|---|---|
| Actual Orifice Diameter D₀ | 23 - 92 Mm | 0.91 - 3.62 In |
| Actual Orifice Area A₀ | 416 - 6648 Mm² | 0.645 - 10.304 In² |
| Pressure | 0.1 - 16 Bar | 1.45 - 232 Psig |
| Temperature (in Accordance With DIN EN) | -270 To 450 °C | -121 To 392 °F |
| Nominal Diameter At Inlet | DN 25 - DN 150 | 1" - 6" |
|---|---|
| Actual Orifice Diameter D₀ | 23 - 125 Mm | 0.98 - 4.92 In |
| Actual Orifice Area A₀ | 416 - 12272 Mm² | 0.65 - 19 In² |
| Pressure | 0.5 - 1 Bar | 7.2 - 14.5 Psig |
| Flange Rating Inlet | PN 16 | PN16 |
| Product Name | Endress+Hauser Radar Level Micropilot FMR60 For High Demands Liquid |
|---|---|
| Accuracy | +/- 1 Mm (0.04 In) |
| Process Temperature | -40...+130 °C (-40...+266 °F) |
| Process Pressure | Absolute / Max. Overpressure Limit Vacuum16 Bar (Vacuum232 Psi) |
| Max. Measurement Distance | 50 M (164 Ft) |
| Area Classification | ATEX Group II Category 2 Gas And Dust, CUTR For Groups II/III Category 2 Equipment |
|---|---|
| Communication Protocol | 3-15 Or 6-30 Psi, 0.2 -1.0 Or 0.4 -2.0 Bar Pneumatic Signal |
| Diagnostics | No |
| Input Signal | Pneumatic |
| Max Outlet Pressure | 90 Psi |
| Model Number | TZIDC-200 |
|---|---|
| Storage Temperature Limits | -58°F To 200°F (-50°C To 93°C) |
| Relative Humidity | 10 To 90% Non-condensing |
| Fast Transient Burst | No Effect At 2 KV |
| Customized Support | OEM, ODM, OBM |
| Model Number | TZIDC-200 |
|---|---|
| Storage Temperature Limits | -58°F To 200°F (-50°C To 93°C) |
| Relative Humidity | 10 To 90% Non-condensing |
| Fast Transient Burst | No Effect At 2 KV |
| Customized Support | OEM, ODM, OBM |
| Model Number | TZIDC-200 |
|---|---|
| Storage Temperature Limits | -58°F To 200°F (-50°C To 93°C) |
| Relative Humidity | 10 To 90% Non-condensing |
| Fast Transient Burst | No Effect At 2 KV |
| Customized Support | OEM, ODM, OBM |
| Model Number | TZIDC-200 |
|---|---|
| Storage Temperature Limits | -58°F To 200°F (-50°C To 93°C) |
| Relative Humidity | 10 To 90% Non-condensing |
| Fast Transient Burst | No Effect At 2 KV |
| Customized Support | OEM, ODM, OBM |
| Maximum Outlet Pressure | 450 Psig / 31.0 Bar |
|---|---|
| Inlet Pressure Range | 500 To 2400 Psig (34.5 To 165.5 Barg) |
| Degree Of Protection | IP 54 |
| Supply Media | Air, Natural Gas |
| Product Type | Pressure/Vacuum Relief Valves |