| Process Temperature(Standard) | -40 To +125 °C (-40 To +257 °F) |
|---|---|
| Process Connections | Threaded, Flange, Hygienic, Remote Seal |
| Applications | Hygienic, Chemical, And Oil & Gas Applications |
| Wetted Materials | 316L Stainless Steel, Alloy C, Tantalum (optional) |
| Output Signal | 4 To 20 MA With HART |
| Process Temperature(Standard) | -40 To +125 °C (-40 To +257 °F) |
|---|---|
| Process Connections | Threaded, Flange, Hygienic, Remote Seal |
| Applications | Hygienic, Chemical, And Oil & Gas Applications |
| Wetted Materials | 316L Stainless Steel, Alloy C, Tantalum (optional) |
| Output Signal | 4 To 20 MA With HART |
| Measuring Principle | Vibration Liquids |
|---|---|
| Ambient Temperature | -50 °C...+70 °C (-58 °F...+158 °F) |
| Process Temperature | -50 °C...+150 °C (-58 °F...+302 °F) |
| Process Pressure / Max. Overpressure Limit | Vacuum...100 Bar |
| Min. Density Of Medium | 0.5g/cm³(0.4g/cm³ Optional) |
| Measuring Principle | Vibration Liquids |
|---|---|
| Ambient Temperature | -50 °C...+70 °C (-58 °F...+158 °F) |
| Process Temperature | -50 °C...+150 °C (-58 °F...+302 °F) |
| Process Pressure / Max. Overpressure Limit | Vacuum...100 Bar |
| Min. Density Of Medium | 0.5g/cm³(0.4g/cm³ Optional) |
| Measuring Principle | Vibration Liquids |
|---|---|
| Ambient Temperature | -50 °C...+70 °C (-58 °F...+158 °F) |
| Process Temperature | -50 °C...+150 °C (-58 °F...+302 °F) |
| Process Pressure / Max. Overpressure Limit | Vacuum...100 Bar |
| Min. Density Of Medium | 0.5g/cm³(0.4g/cm³ Optional) |
| Material | 316L , AlloyC |
|---|---|
| Process Temperature | -70°C...400°C (-94°F...752°F) |
| Max. Measurement Distance | 4000m (13.123ft) H2O |
| Max. Overpressure Limit | 600 Bar (9000 Psi) |
| Measuring Cell | 400 Mbar...400 Bar(5.8 Psi...6000 Psi)relative/ Absolute |
| Product Name | Radar Measurement Micropilot FMR67 |
|---|---|
| Max. Measurement Distance | 125 M (410 Ft) |
| Process Temperature | -40...+200 °C(-40...+392 °F) |
| Measuring Principle | Level Radar Solid |
| Communication | 4...20 MA HART |
| Max. Process Pressure | PN 100, Class 600, 20K |
|---|---|
| Outputs | 4-20 MA HART (passive) |
| Digital Communication | HART, PROFIBUS PA, FOUNDATION Fieldbus |
| Max. Measurement Error | Volume Flow (standard): ±0.5 % O.r. ± 1 Mm/s (0.04 In/s) |
| Power Supply | DC 12 To 35 V |
| Product Name | Radar Measurement Micropilot FMR56 |
|---|---|
| Process Pressure/max. Overpressure Limit | Vacuum...3 Bar(Vacuum...43.5 Psi) |
| Process Connection | UNI DN80...DN150(3"...6") |
| Communication | 4...20 MA HART PROFIBUS PA FOUNDATION Fieldbus |
| Measuring Principle | Level Radar Solid |
| Wetted Materials | 316L Stainless Steel, Alloy C, Tantalum (optional) |
|---|---|
| Output Signal | 4 To 20 MA With HART |
| Applications | Hygienic, Chemical, And Oil & Gas Applications |
| Process Temperature(Standard) | -40 To +125 °C (-40 To +257 °F) |
| Packaging Details | Carton + Wooden Box + Protection |