| Measuring Principle | Potentiometric |
|---|---|
| Process Temperature | -15 To 80 °C (5 To 176 °F) |
| Temperature Sensor | NTC 30K |
| Process Pressure | 0.8 To 17 Bar (11.6 To 246.5 Psi) Absolute |
| Dimension | 12 Mm (0.47 Inch) |
| Measuring Principle | Potentiometric |
|---|---|
| Process Temperature | -15 To 80 °C (5 To 176 °F) |
| Temperature Sensor | NTC 30K |
| Process Pressure | 0.8 To 17 Bar (11.6 To 246.5 Psi) Absolute |
| Dimension | 12 Mm (0.47 Inch) |
| Measuring Principle | Potentiometric |
|---|---|
| Process Temperature | -15 To 80 °C (5 To 176 °F) |
| Temperature Sensor | NTC 30K |
| Process Pressure | 0.8 To 17 Bar (11.6 To 246.5 Psi) Absolute |
| Dimension | 12 Mm (0.47 Inch) |
| Weight | 10-20KG |
|---|---|
| Material Certificates | 3.1 Material NACE MR0175/MR0103, PMI; Welding Test Acc. To EN ISO, ASME, NORSOK |
| Product Safety | CE, C-tick, EAC Marking |
| Functional Safety | Functional Safety According To IEC 61508, Applicable In Safety-relevant Applications In Accordance With IEC 61511 |
| Model | Proline Promass F 500 |
| Process Temperature(Standard) | -40 To +125 °C (-40 To +257 °F) |
|---|---|
| Process Connections | Threaded, Flange, Hygienic, Remote Seal |
| Applications | Hygienic, Chemical, And Oil & Gas Applications |
| Wetted Materials | 316L Stainless Steel, Alloy C, Tantalum (optional) |
| Output Signal | 4 To 20 MA With HART |
| Process Temperature(Standard) | -40 To +125 °C (-40 To +257 °F) |
|---|---|
| Process Connections | Threaded, Flange, Hygienic, Remote Seal |
| Applications | Hygienic, Chemical, And Oil & Gas Applications |
| Wetted Materials | 316L Stainless Steel, Alloy C, Tantalum (optional) |
| Output Signal | 4 To 20 MA With HART |
| Measuring Principle | Vibration Liquids |
|---|---|
| Ambient Temperature | -50 °C...+70 °C (-58 °F...+158 °F) |
| Process Temperature | -50 °C...+150 °C (-58 °F...+302 °F) |
| Process Pressure / Max. Overpressure Limit | Vacuum...100 Bar |
| Min. Density Of Medium | 0.5g/cm³(0.4g/cm³ Optional) |
| Measuring Principle | Vibration Liquids |
|---|---|
| Ambient Temperature | -50 °C...+70 °C (-58 °F...+158 °F) |
| Process Temperature | -50 °C...+150 °C (-58 °F...+302 °F) |
| Process Pressure / Max. Overpressure Limit | Vacuum...100 Bar |
| Min. Density Of Medium | 0.5g/cm³(0.4g/cm³ Optional) |
| Measuring Principle | Vibration Liquids |
|---|---|
| Ambient Temperature | -50 °C...+70 °C (-58 °F...+158 °F) |
| Process Temperature | -50 °C...+150 °C (-58 °F...+302 °F) |
| Process Pressure / Max. Overpressure Limit | Vacuum...100 Bar |
| Min. Density Of Medium | 0.5g/cm³(0.4g/cm³ Optional) |
| Product Name | Radar Measurement Micropilot FMR67 |
|---|---|
| Max. Measurement Distance | 125 M (410 Ft) |
| Process Temperature | -40...+200 °C(-40...+392 °F) |
| Measuring Principle | Level Radar Solid |
| Communication | 4...20 MA HART |