| Packaging Details | Packing type: cardboard box/non-fumigation wooden box |
|---|---|
| Brand Name | FOXBORO |
| Model Number | FOXBORO SRD991 |
| Diagnostics | Yes |
|---|---|
| Construction / Materials | Copper-free Aluminum Housing |
| Operating Temperature | -50°C To +85°C |
| Pneumatics Action | Single Or Double Acting, Fail Safe/Rotary And Linear |
| Supply Pressure(Single-Acting) | 20 To 100 Psi Max (1.4 To 6.9 Bar) |
| Communication Protocol | 4-20 MA HART |
|---|---|
| Output Signal | Pneumatic Pressure Up To 145 Psig (10 Bar) |
| Protection Rating | IP66/IP67 |
| Power Supply | 24V DC |
| Diagnostic Functions | Real-time Valve Health Monitoring And Performance Diagnostics |
| Operating Temperature | -50°C To +85°C |
|---|---|
| Supply Pressure(Single-Acting) | 20 To 100 Psi Max (1.4 To 6.9 Bar) |
| Air Delivery | 280 SLPM @ 30psi |
| Fits Many Applications | Rotary Or Linear ;Remote Or Local |
| Supply Pressure(Double-Acting) | 20 To 150 Psi Max (1.4 To 10.3 Bar) |
| Input Signal Range | 4 - 20 MA HART |
|---|---|
| Protection | IP66 |
| Air Supply Pressure | 1.4 To 7.0 Bar |
| Weight Of Valve Positioner | 2.5 Kg (5.5 Lb) |
| Packaging Details | Cardboard box |
| Brand / Manufacturer | Masoneilan |
|---|---|
| Supply Air Pressure | Typically 1.4 To 7 Bar (20 To 100 Psig) |
| Process/Valve Temperature Range | -196°C To +450°C |
| Hazardous Area Approvals | ATEX, IECEx, FM, CSA (for Certified Models) |
| Mounting | Direct Mount On Linear (stem) Or Rotary (ISO 5211) Actuators |
| Operating Temperature Limits | -58°F To 185°F (-50°C To 85°C) |
|---|---|
| Supply Pressure Effect | 0.05% Per Psi |
| Insulation Resistance | Greater Than 10 G Ohms At 50% RH |
| Fast Transient Burst | No Effect At 2 KV |
| Relative Humidity | 10 To 90% Non-condensing |
| Power Supply | Two-wire, 4-20 MA ,10.0 VDC Plus Line Losses |
|---|---|
| Input Signal Range | 4 - 20 MA |
| Compliance Voltage | 10 To 32 VDC @ 20 MA |
| Effective Resistance | 500 Ω @ 20 MA Typical |
| Communications | HART Protocol (Logix 382X- Only) |
| Supply Media | Air, Natural Gas |
|---|---|
| Diagnostics | Yes |
| Max Outlet Pressure | 145 Psig |
| Communication Protocol | HART |
| Process Control | Flow, Pressure, Temperature, Level |
| Input Signal Range | 4-20 MA (split Range Minimum Amplitude 8 MA) |
|---|---|
| Air Supply | 20 To 100 Psig (regulate 5 To 10 Psi Above Actuator Spring Range) |
| Actuator Stroke | 20 Mm To 150 Mm Or 55 ° To 90 ° |
| Action | Single Acting/fail Vent/Double Acting |
| Operating Temperature | -4 °F To +158 °F |