| Nominal Diameter At Inlet | DN 25 - DN 150 | 1" - 6" |
|---|---|
| Actual Orifice Diameter D₀ | 23 - 125 Mm | 0.98 - 4.92 In |
| Actual Orifice Area A₀ | 416 - 12272 Mm² | 0.65 - 19 In² |
| Pressure | 0.5 - 1 Bar | 7.2 - 14.5 Psig |
| Flange Rating Inlet | PN 16 | PN16 |
| Nominal Diameter At Inlet | DN 15 - DN 20 | 3/4" - 1" |
|---|---|
| Actual Orifice Diameter D₀ | 13 - 17.5 Mm | 0.51 - 0.69 In |
| Actual Orifice Area A₀ | 133 - 241 Mm² | 0.21 - 0.37 In² |
| Pressure | 1 - 10 Bar | 14.5 - 145 Psig |
| Temperature (in Accordance With DIN EN) | Up To 120 °C | Up To 248 °F |
| Nominal Diameter At Inlet | DN 25 - DN 200 | 1" - 8" |
|---|---|
| Orifice | API Standard As Well As Extra Orifice: 1 D 2 - 8 T 10 / 1 G 2 - 8 T+ 10 |
| Actual Orifice Diameter D₀ | 11 - 190 Mm | 0.433 - 7.087 In |
| Actual Orifice Area A₀ | 95 - 25446.9 Mm² | 0.147 - 39.443 In² |
| Pressure | 2.5 - 256 Bar | 36 - 3705 Psig |
| Nominal Diameter At Inlet | DN 25 - DN 200 | 1" - 8" |
|---|---|
| Orifice | API Standard As Well As Extra Orifice: 1 D 2 - 8 T 10 / 1 G 2 - 8 T+ 10 |
| Actual Orifice Diameter D₀ | 11 - 180 Mm | 0.433 - 7.087 In |
| Actual Orifice Area A₀ | 95 - 25446.9 Mm² | 0.147 - 39.443 In² |
| Pressure | 2.5 - 426 Bar | 36 - 6170 Psig |
| Operating Limits Valve Size | DN 25 - DN 400 | 1" - 16" |
|---|---|
| Operating Limits Pressure Class Inlet Flange | PN10 - PN400 | CL150 - CL2500 |
| Design | Pneumatically, Electropneumatically |
| Max. Operating Pressure | 315 Bar |
| Anbau An Type | 441 Up To DN 400, 457 Up To DN 150, 526 Up To DN 200 |
| Area Classification | Intrinsically Safe, Non-incendive For CSA And FM |
|---|---|
| Communication Protocol | HART, 4-20mA Analog |
| Data Interface | Wired |
| Diagnostics | Yes |
| Input Signal | Electric |
| Area Classification | Intrinsically Safe, Non-incendive For CSA And FM |
|---|---|
| Communication Protocol | HART, 4-20mA Analog |
| Data Interface | Wired |
| Diagnostics | Yes |
| Input Signal | Electric |
| Area Classification | Explosion Proof, Intrinsically Safe, FISCO, Type N, Flame Proof, Non-incendive For FM |
|---|---|
| Communication Protocol | Profibus |
| Data Interface | Wired |
| Diagnostics | Yes |
| Input Signal | Electric |
| Area Classification | ATEX Group II Category 2 Gas And Dust, CUTR For Groups II/III Category 2 Equipment |
|---|---|
| Communication Protocol | 3-15 Or 6-30 Psi, 0.2 -1.0 Or 0.4 -2.0 Bar Pneumatic Signal |
| Diagnostics | No |
| Input Signal | Pneumatic |
| Max Outlet Pressure | 150 Psi |
| Certifications | CRN, CUTR, Fugitive Emission, PED, SIL Capable |
|---|---|
| Critical Service | Noise Abatement, Cavitation, Erosive, Low Flow, Corrosive, General Service |
| Flow Characteristics | Equal Percentage, Linear, Special Characterization |
| Material | Carbon Steel, Stainless, Duplex, Alloy |
| Operating Temperature | Standard Temperature, High Temperature |