| Accessories | Overload Protection, Manual Operation, Protective Cover, And Transition Plate |
|---|---|
| Positioning Accuracy | Typically ±0.5% |
| Operating Temperature Range | -40°C To +85°C |
| Mounting | Vertical Or Suspended Mounting Options |
| Power Supply Voltage | 24VDC Or 110-240VAC |
| Protection Level | IP66 |
|---|---|
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
| Diagnostic Function | It Can Automatically Detect Faults And Device Status, And Provide Warning And Fault Prompt Information |
| Local Display | 4-digit LCD Screen, Which Can Display Current Analog Input Value, Output Value, Set Value, And Device Status Information |
| Power Supply | 12-42V DC Power Supply |
| Input Signal | 4-20mA DC, 1-5V DC, 0-10V DC, HART Protocol, Etc |
|---|---|
| Protection Level | IP66 |
| Diagnostic Function | It Can Automatically Detect Faults And Device Status, And Provide Warning And Fault Prompt Information |
| Accuracy | Up To 0.075% Under Nominal Conditions |
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
| Operating Temperature Range | -40℃ To 70℃ |
|---|---|
| Digital Communication Interface | Optional RS485 Modbus RTU Or FOUNDATION Fieldbus Interface |
| Protection Level | IP66 |
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
| Diagnostic Function | It Can Automatically Detect Faults And Device Status, And Provide Warning And Fault Prompt Information |
| Measuring Cell | 400 Mbar...10 Bar (6 Psi...150psi) |
|---|---|
| Diagnostics | Basic Diagnostics, Loop Integrity |
| Flow Characteristics | Linear, Equal Percentage, Quick Opening |
| Protection | IP65/IP67 |
| Pressure Rating | 150 - 600 Psi |
| Area Classification | Explosion Proof, Intrinsically Safe, Non-incendive, Dust Certifications CSA, FM, ATEX, IECEx, CUTR, Peso, KGS, INMETRO, NEPSI, R |
|---|---|
| Certifications | CSA, FM, ATEX, IECEx, CUTR, Peso, KGS, INMETRO, NEPSI, RCM |
| Communication Protocol | 4-20mA Analog |
| Data Interface | Wired |
| Diagnostics | No |
| Measurement Range | 0-24 MA DC |
|---|---|
| Display | LCD Display, 2 Lines X 16 Characters |
| Output Resolution | 0.001 MA |
| Battery Life | Approx. 20 Hours Continuous Use At 20 MA Output |
| Accuracy | 0.025% Full Scale |
| Rated Flow Coefficient | Maximum CV Value Of 470 |
|---|---|
| Output Signal | 4-20mA, HART, PROFIBUS PA Or FOUNDATION Fieldbus |
| Valve Position Feedback | Provides Digital Position Feedback Through Hall Sensors Or Analog Position Feedback Through Potentiometers |
| Protection Rating | IP66/67 |
| Valve Travel Range | 10mm To 100mm |
| Conformity/Linearity | ± 0.5% Full Span |
|---|---|
| Supply Pressure Effect | 0.05% Per Psi Unit |
| Name | Masoneilan SVI FF |
| Operating | -40° F To 185° F (-40° C To 85° C) |
| Accuracy | ± 0.5% |
| Rated Flow Coefficient | Maximum CV Value Of 470 |
|---|---|
| Valve Connection | ISO 5211 Direct Mounting Or VDI/VDE 3845 Mounting With Adapter |
| Material | Aluminum Alloy Or Stainless Steel |
| Valve Travel Range | 10mm To 100mm |
| Zero Point Drift | Less Than 0.1% Of The Maximum Travel Value |