| Operating Temperature | -76 To 392 °F (-60 To 200 °C) |
|---|---|
| Communication Protocol | 4-20mA HART7,WirelessHAR |
| Material | Brass, Aluminum Alloy |
| Accuracy | ± 2 Mm |
| Power Supply | 12-35 VDC (30 VDC In Intrinsically Safe Installations) |
| Accuracy | ± 2 Mm |
|---|---|
| Power Supply | 12-35 VDC (30 VDC In Intrinsically Safe Installations) |
| Measurement Frequency | 80 GHz |
| Antenna Type | Process Seal, Lens Antenna, ATAP Lens Antenna |
| Operating Temperature | -76 To 392 °F (-60 To 200 °C) |
| Wetted Material | Stainless Steel; 316 / 316L And CF3M |
|---|---|
| Wireless Update Rate | 1 Sec. To 60 Min., User Selectable |
| Flange Options | ANSI Class 150 To 1500 |
| Temperature Range | -200°C To +850°C |
| Power Module Life | Up To 10-year Life, Field Replaceable (order Separately) |
| Operating Temperature | -76 To 392 °F (-60 To 200 °C) |
|---|---|
| Communication Protocol | 4-20mA HART7,WirelessHAR |
| Material | Brass, Aluminum Alloy |
| Accuracy | ± 2 Mm |
| Power Supply | 12-35 VDC (30 VDC In Intrinsically Safe Installations) |
| Accuracy | ± 2 Mm |
|---|---|
| Power Supply | 12-35 VDC (30 VDC In Intrinsically Safe Installations) |
| Measurement Frequency | 80 GHz |
| Antenna Type | Process Seal, Lens Antenna, ATAP Lens Antenna |
| Operating Temperature | -76 To 392 °F (-60 To 200 °C) |
| Temperature Range | -200°C To +850°C |
|---|---|
| Weight | Depends On Specific Instrument |
| Flange Options | ANSI Class 150 To 1500 |
| Precision | High Precision |
| Wireless Update Rate | 1 Sec. To 60 Min., User Selectable |
| Output / Protocol | 4-20 MA With HART; FOUNDATION Fieldbus; PROFIBUS PA |
|---|---|
| Display/Interface | LCD Display, LCD Display With Local Operator Interface (LOI), Or LED |
| IP Rating | IP66 |
| Mounting / Housing | Head Mount (DIN A), Field Mount, Rail Mount |
| Diagnostics | Yes |
| Output Signal | 4 To 20 MA With HART |
|---|---|
| Protection | IP66/67 (option: IP68) |
| Actuator | Electric |
| Conditional | New |
| Temperature Sensor | Thermistor |
| Display Type | LCD Display |
|---|---|
| Temperature Resolution | 0.05°C |
| Communication Interface | HART, FOUNDATION Fieldbus, Profibus PA |
| Material | Aluminum, Stainless Steel |
| Warranty | 1 Year |
| Accuracy | ± 2 Mm |
|---|---|
| Power Supply | 12-35 VDC (30 VDC In Intrinsically Safe Installations) |
| Measurement Frequency | 80 GHz |
| Antenna Type | Process Seal, Lens Antenna, ATAP Lens Antenna |
| Operating Temperature | -76 To 392 °F (-60 To 200 °C) |