| Product Name | Samson Control Valve With Positioner 3766,3767 Valve Positioner |
|---|---|
| Brand | SAMSON |
| Model | XYZ-123 |
| Matrial | Alloy/Steel |
| Torque | 34~13500Nm |
| Output Modules | P/P (3-15 Psi) Or I/P (4-20 MA; Optional 10-50 MA) |
|---|---|
| Supply Pressure Tolerance | Up To 150 Psi Without External Regulator |
| Shock & Vibration Handling | Up To 2 G And 500 Hz Vibration Frequency Support |
| Signal Split Range | 2-, 3-, Or 4-way Split Range |
| Air Consumption | ~0.25 SCFM (steady State) / Up To 0.31 SCFM (I/P Module) |
| Application | General |
|---|---|
| Material | Casting |
| Temperature Of Media | Medium Temperature |
| Pressure | Medium Pressure |
| Power | Pneumatic |
| Product Name | CChinese Control Valve Flowserve Logix 3200 Series 3200MD-28-D6-E-04-40-0G-00 Valve Psotitioner With Asco 342A SST Air Regulator |
|---|---|
| Model | 3200MD-28-D6-E-04-40-0G-00/3200MD-28-D6-E-04-40-0G-0F |
| Temperature Of Media | High Temperature |
| Pressure | High Pressure |
| Operating Temperature | -20 To 55°C (-4 To 122°F) |
| Output Modules | P/P (3-15 Psi) Or I/P (4-20 MA; Optional 10-50 MA) |
|---|---|
| Supply Pressure Tolerance | Up To 150 Psi Without External Regulator |
| Shock & Vibration Handling | Up To 2 G And 500 Hz Vibration Frequency Support |
| Signal Split Range | 2-, 3-, Or 4-way Split Range |
| Air Consumption | ~0.25 SCFM (steady State) / Up To 0.31 SCFM (I/P Module) |
| Product Name | Chinese Control Valves Positioner Flowserve Logix 3200 Series 3200MD-28-D6-E-04-40-0G-00 Asco Regulator YT-300 Booster Stock |
|---|---|
| Model | 3200MD-28-D6-E-04-40-0G-00/3200MD-28-D6-E-04-40-0G-0F |
| Temperature Of Media | High Temperature |
| Pressure | High Pressure |
| Operating Temperature | -20 To 55°C (-4 To 122°F) |
| Output Modules | P/P (3-15 Psi) Or I/P (4-20 MA; Optional 10-50 MA) |
|---|---|
| Supply Pressure Tolerance | Up To 150 Psi Without External Regulator |
| Shock & Vibration Handling | Up To 2 G And 500 Hz Vibration Frequency Support |
| Signal Split Range | 2-, 3-, Or 4-way Split Range |
| Air Consumption | ~0.25 SCFM (steady State) / Up To 0.31 SCFM (I/P Module) |
| Air Consumption | 0.082 Nm³/h @ 4.1 Bar(0.048 SCFM @ 60 Psi) |
|---|---|
| Sensitivity | ≤ 0.25 % |
| Communications | HART 6 And 7 |
| Output Air Capacity | 20.8 Nm³/h @ 4.1 Bar(12.2 SCFM @ 60 Psi) |
| Customized Support | OEM |
| Input Signal | 4-20 MA HART |
|---|---|
| Air Supply | 1.4 To 10.3 Bar (20 To 150 Psig) |
| Protection Rating | IP66 |
| Operating Temperature | -40°C To 80°C (-40°F To 176°F) |
| Communication Protocol | HART 6/7 |
| Temperature Range | -40 ... +85 °C / -40 ... +185 °F, Standard Version |
|---|---|
| Temperature Range(arctic Version) | -53 ... +85 °C / -63 +185 °F |
| Communication | HART, FOUNDATION Fieldbus, Profibus PA |
| Protection Class | IP66 / NEMA 4X Enclosure |
| Supply Power | Loop Powered, 4-20 MA |