| Input Signal | 4-20 MA DC |
|---|---|
| Communication Protocols | SP7-10: HART 5/7, SP7-11: PROFIBUS PA, SP7-12: Foundation Fieldbus |
| Humidity | 0 To 100% RH (non-condensing) |
| Operating Temperature | -40 ℃ ~ 85 ℃ |
| Highlight | Spirax Sarco SP7 valve positioner,electro pneumatic valve positioner,4-20 mA HART positioner |
| Input Pressure | 1.4...6 Bar |
|---|---|
| Ambient Air Temperature For Operation | -40...80 °C (-40...176 °F) |
| Communication Port Protocol | HART, 4...20 MA Profibus FOUNDATION Fieldbus |
| IP Degree Of Protection | IP66 |
| Maximum Pressure | 6 Bar ,90 Psi |
| Input Pressure | 1.4...6 Bar |
|---|---|
| Ambient Air Temperature For Operation | -40...80 °C (-40...176 °F) |
| Communication Port Protocol | HART, 4...20 MA Profibus FOUNDATION Fieldbus |
| IP Degree Of Protection | IP66 |
| Maximum Pressure | 6 Bar ,90 Psi |
| Input Signal | 4-20 MA |
|---|---|
| Supply Pressure | 1.4 - 7 Bar (20 - 100 Psi) |
| Operating Temperature | -40°C To +85°C |
| Enclosure Protection | IP66 / NEMA 4X |
| Repeatability | ≤0.5% |
| Input Signal | 4-20 MA |
|---|---|
| Supply Pressure | 1.4 -7 Bar (20 -100 Psi) |
| Operating Temperature | -40°C To +85°C |
| Enclosure Protection | IP66 / NEMA 4X |
| Air Consumption | Low Consumption |
| Operating Temp. Range | -40°C To +85°C |
|---|---|
| Communication Protocol | HART (optional) |
| Repeatability | ≤0.5% |
| Enclosure Protection | IP66 / NEMA 4X |
| Air Consumption | Low Consumption Design |
| Communication Protocol | HART 7 |
|---|---|
| Maximum Output Pressure | 145 Psig |
| Input Signal | 4-20 MA DC, 24 VDC |
| Position Control | Throttling Control, On/off |
| Media Supply | Air Or Natural Gas |
| Input Current Range | 4~20mA DC |
|---|---|
| Air Source Connection Size | PT1/4, NPT1/4 |
| Ingress Protection Rating | IP66 |
| Input Pressure Range | 0.14~0.7MPa |
| Pressure Gauge Connection Size | PT1/8, NPT1/8 |
| Class Of Protection | IP65 |
|---|---|
| Temperature Range | -40 ... + 50°C /-40 ... + 65°C |
| Input | 4-20mA |
| Condition | New |
| Highlight | Valmet control valve positioner,Neles ND9000 smart valve controller,ND9200 digital valve positioner |
| Temperature Range | -40 ... +85 °C / -40 ... +185 °F, Standard Version |
|---|---|
| Protection Class | IP66 |
| Feature | SIL 2 Approved Device |
| Communication | HART, FOUNDATION Fieldbus, Profibus PA |
| Highlight | ND9000 Series intelligent valve positioner,aluminum stainless steel valve controller,pneumatic control valve with diagnostics |