| Product Name | Radar Measurement Micropilot FMR56 |
|---|---|
| Process Pressure/max. Overpressure Limit | Vacuum...3 Bar(Vacuum...43.5 Psi) |
| Process Connection | UNI DN80...DN150(3"...6") |
| Communication | 4...20 MA HART PROFIBUS PA FOUNDATION Fieldbus |
| Measuring Principle | Level Radar Solid |
| Product Name | Endress+Hauser Radar Level Micropilot FMR20 For Water & Wastewater |
|---|---|
| Accuracy | +/- 2 Mm (0,08") |
| Process Temperature | -40...+80°C (-40...+176°F) |
| Process Pressure Absolute | -1...3 Bar (-14,5...43 Psi) |
| Max. Measurement Distance | 15 M (49.2 Ft), DN80_ 20 M (65.6 Ft) |
| Measuring Principle | Electromagnetic |
|---|---|
| Output Signal | 4–20 MA, HART, Modbus, Profibus, EtherNet/IP |
| Special Features | Heartbeat Technology, Touch Control, Backlit Display |
| Ingress Protection | IP66/67 (standard), IP68 (optional) |
| Maximum Pressure | PN 40 / Class 300 |
| Product Name | Radar Measurement Micropilot FMR62 |
|---|---|
| Process Pressure/max. Overpressure Limit | Vacuum...+25 Bar(Vacuum...+362.6 Psi) |
| Measuring Principle | Level Radar |
| Communication | 4...20 MA HART |
| Process Temperature | -40...+200 °C (-40...+392 °F) |
| Accuracy | ±0.15 % |
|---|---|
| Material | Stainless Steel |
| Medium Temperature Range | -40 To +150 °C (-40 To +302 °F) |
| Degree Of Protection | Standard: IP66/67, Type 4X Enclosure IP69 |
| Max. Process Pressure | PN 100, Class 600, 63K |
| Process Temperature | -40°C To +150°C |
|---|---|
| Protection Class | IP68 (standard) |
| Output Signal | 4-20mA+HART, Optional Profibus PA/FF/Profinet |
| Power Supply | 10.5-35V DC (Ex I: 10.5-30V DC) |
| Accuracy | ±0.075% (standard), ±0.025% (Platinum) |
| Measuring Range | 100 Mbar To 40 Bar (absolute/gauge) |
|---|---|
| Process Temperature | -40°C To +100°C |
| Protection Class | IP67 (standard), IP68 (optional) |
| Output Signal | 4-20mA+HART, Optional Profibus PA/FF |
| Power Supply | 10.5-35V DC (Ex I: 10.5-30V DC) |
| Ambient Temperature | -50...+80 °C (-58...+176 °F) |
|---|---|
| Sensor Length | Rod Probe: 10 M /Rope Probe: 45 M /Coaxial Probe: 6 M |
| Communication | 4...20 MA HART PROFIBUS PA FOUNDATION Fieldbus |
| Process Pressure/max. Overpressure Limit | Vacuum...400 Bar (Vacuum...5800 Psi) |
| Material | Stainless Steel |
| Product Name | Proline Promass F 300 Coriolis Flowmeter |
|---|---|
| Nominal Diameter Range | DN 8 To 250 |
| Measuring Range | 0 To 2 200 000 Kg/h (0 To 80 840 Lb/min) |
| Max. Process Pressure | PN 100, Class 600, 63K |
| Sensor Housing Material | Standard: 1.4301 (304) /Option: 1.4404 (316/316L) |
| Accuracy | Standard: Up To 0.05 % |
|---|---|
| Process Temperature | -40°C...+110°C |
| Rated Temperature | -40~200℃ |
| Communication Interface | Depends On Specific Instrument |
| Condition | New |